CEO Đoàn Văn Hoàng – HRT share how to evaluate HVAC efficiency by actual data to reduce power properly, control cause and still maintain operation quality.
HVAC Efficiency Assessment: Measure the right new power reduction properly

Imagine an operation meeting at the beginning of the month.
Person in charge of reporting:
“HVAC power this month drops 12%"
I'm not going to rush into a success.
I want to know how many hours the construction is running this month.
Has the number of users changed?
Are there any areas where air conditioning time is cut off?
Does the temperature and humidity still meet the requirements?
Does a crowded meeting room generate reflections?
Because to me, HVAC efficiency assessments do not seek to make the power meter run the slowest.
The goal is to use less energy to do same task or a more defined task.
The power is down, but the service quality is down.
Don't start with electricity bills
Your electric bill will tell you how much energy your business uses.
It doesn't explain itself why electricity rises or falls.
A month cooler could lower the air conditioning.
A floor less occupied by people can also reduce electricity.
A shutdown area can produce very nice results on the report.
If you don't know how the conditions have changed, it's hard to tell if the system is actually more efficient.
So when I look at HVAC power, I want to put the power data next to the operation data.
How many hours does the work run?
how is actual load?
What's the temperature outside?
Did you change the function?
Is Setpoint being adjusted?
That's the context that needs to be before a kWh number becomes a decision - making base.
Before you measure, you have to know what you're measuring.

One of the most common errors when comparing HVAC performance is that the two parties are talking about two different ranges.
For example, the Chiller Station.
One report only counts the Chiller power.
Other reports include chilled-water pump, condenser water pump and tower fan.
Both of them could be true.
But they can't be put side by side and then conclude which system is more effective.
The original HRT also emphasized that the measurement boundary must be determined from the beginning: is assessing the equipment or the whole station separately, what load is calculated and where is the cooling capacity determined.
I want this question resolved before the tech team starts publishing reports.
An index that does not have a clear range is easy to make a clear but false conclusion.
kWh decrease does not necessarily increase efficiency
This is a very easy to mistake project owner point.
Suppose the chiller ran high load yesterday and used a lot of kW.
Today's load is lower, so power capacity is down.
If you look at kW only, today looks better.
But it's creating less cooling capacity.
To evaluate performance, one must see how much electricity is being used to generate refrigeration under that condition.
That's why indicators like COP or kW/RT are valuable when evaluating refrigeration equipment and stations.
kWh, meanwhile, answers another question: how much electricity the system has used over a period of time.
The original HRT also distinguishes the performance indicators such as COP, EER, kW/TR from consumption indicators such as kWh; the two groups serve different purposes and should be read in the right context.
I don't want the operations team picking an indicator and then forcing it to answer every question.
A good indicator must come with reliable input data
Suppose the BMS table displays kW/RT nicely.
I still want to know where that number came from.
Is the power measured directly or estimated?
What water flow rate is derived from the flow meter?
Temperature sensor level and feedback have been checked yet?
Do the data have the same timestamp?
If the flow rate is wrong or the two temperature sensors are significantly offset, the cooling capacity calculation is also wrong.
The system can then create a very professional dashboard but decide to operate again based on unreliable data.
I always remind the engineering team:
Don't optimize a number before checking the quality of the data that generates it.
To reduce power, first find the running part that does not generate value

Before thinking of replacing Chiller, installing variable-frequency drive or investing in new control system, I want to check the operation schedule.
This is usually where the most visible opportunities are.
One floor of offices closed at 18: 00 but air conditioning remained on until 21: 00.
A meeting room that only uses a few hours a day but is running the same schedule as the whole floor.
A system overtime was set to manual override but no one returned the schedule.
Such cases do not require new equipment.
They require a more explicit operational process.
However, I don't think of all my overtime as a waste either.
There IT area needs constant cooling.
There is a technical room to control temperature.
There is production process can not be stopped by office hours.
What to do is identify:
Is the device running because of actual duty or because an operation routine has expired?
After the schedule, look at the setpoint
A system can run on time but still use more electricity than necessary because the control parameters are not consistent.
The room temperature is too low.
Cold water is kept at an unnecessary setpoint during all loads.
The pump always keeps the same pressure despite the load being reduced.
Cooling tower runs more than the total system needs.
Here, I don't want the operator to change the setpoint just because of a chance of saving.
Each setpoint exists for a task.
If you change, you have to know what's going to react.
For example, raising the temperature of cold water can help the chiller reduce compression under certain conditions.
But the AHU may need to open a larger valve.
Water flow rate can be changed.
Dehumidification capacity may be affected.
Electric pumps can increase.
If you just look at electric chillers, the solution seems to work.
If you look at the whole system, the results may be different.
Optimizing HVAC is optimizing the relationship between devices, not beautifying the index of a device.
When the power goes up, do not default to old machines as the cause
A Chiller operation for many years can impair performance.
But device age is not the only proof.
Electricity surges can come from a variety of causes.
Long running schedule.
Load works increase.
Dirty coil or heat exchanger.
Flow rate is incorrect.
Cooling tower no longer works as it used to.
Sensor deflection.
The sequence of running Chiller – pump – tower has not been well coordinated.
HRT breaks down the causes into three categories: those that can be improved by operation, those that need maintenance and those that really need to invest in renovation or replacement.
I think this classification is very important.
Because if the problem is in the schedule, replacing the Chiller does not solve the root of the problem.
If the heat exchanger is dirty, investing more BMS also does not restore the heat exchanger capacity.
Must prove the cause before approving the solution.
Do not optimize the Chiller without forgetting the pump and cooling tower
A water-cooled system is the best example of systems thinking.
If you try to lower the temperature of your condenser water, your chiller may use less power.
But to reach that level, the tower fan may have to run faster.
Chiller power decreased.
Fan power's up.
If you don't add the two parts together, it's easy to see that one is not really optimal.
The same goes for pumps.
Pump speed reductions often have the potential to reduce electricity.
But if the flow rate or differential pressure is too low, the end-of-line AHU may not receive enough water.
The operator reduces the temperature of cold water to compensate for the lack of cold.
The system eventually follows a reverse - adjustment loop.
I want each change to answer two questions:
How much does this device save?
and more importantly:
How's the whole system changed?
VRV/VRF also needs evaluation using practice

With VRV/VRF, catalog performance is still important data.
But the performance of the building is also influenced by how the zones are used.
A VRV system that has the ability to control each room separately but the entire indoor unit is still turned on simultaneously all day, the partition advantage is not well exploited.
One office had only a few overtime workers but the whole floor was still running because the control schedule had not been reorganized.
A less used room but keeping the setpoint low constantly also creates unnecessary load.
So I want to evaluate VRV/VRF not only by outdoor unit.
Must read the history of each indoor unit group.
Load by zone.
Controls.
Outdoor air.
Operating time.
and reflect the reality of users.
Do not reduce power by reducing service quality
This is the line I don't want a savings program crossing.
If a crowded meeting room becomes more convoluted because of reduced outdoor air, that is not optimal.
If the production area temperature exceeds the requirements to reduce power, that is not optimal.
If the increased humidity is unpleasant for the user, it is necessary to review the option.
An effective program must keep the system's mission within the agreed scope.
Therefore, each saving test needs to stop condition.
If the temperature is above the limit.
If the humidity is not reached.
If the disadvantage area is not served.
If the device appears warning.
The alternative must be reevaluated or reverted to the previous state.
Reduction of electricity is the goal. Maintaining the task of the work is a mandatory condition.
Before and after must be measured under comparable conditions
This is where I want the utmost caution.
Let's say we have a solution that brings down the electricity by 10%.
If the optimal post-measuring date has a significantly lower load, that 10% does not fully reflect the effectiveness of the solution.
If the weather is different.
Operation time varies.
Different numbers.
Different setpoints.
The comparison must be adjusted or limited to conclusions.
The original HRT also requires confirmation of savings based on pre-post data under sufficiently similar conditions, and does not extend the results of a short time to savings for the whole month or year when there is no basis.
I want the report to be as accurate as possible.
What's that prove?
Within what range?
What's left unchecked?
It's a valuable technical report.
A good experiment should only change what is needed
If five parameters are changed at the same time and power is reduced, it is difficult for the operations team to know what factors produce efficiency.
I want every experiment to be logical.
Record the current state.
Choose a problem with evidence.
Determine what parameters to adjust.
Expected impact.
Determine your safety limits.
Make changes.
Follow up enough.
Compare.
Then you decide whether to keep it or go back.
This is how to turn energy optimization into a technical process instead of an involuntary series of experiments.
BMS must help find the cause, not just help plot the graph
I like data.
But I don't like dashboards just for viewing.
A good BMS must help the operator answer:
What device is off - schedule?
Which zone still requires refrigeration after business hours?
When did kW/RT change?
Which water temperature starts to deflate?
Which valve is 100% open frequently?
How many times has an alarm appeared?
When the data is just on the screen, it hasn't created a value yet.
When data leads to a responsible action, it becomes a management tool.
Power saving does not end after acceptance testing date
A system can be very effective right after the optimal phase.
Three months later, the condition may change.
Dirty filter.
Heat exchanger reduces efficiency.
History changes.
A forgotten manual override.
Setpoint is corrected.
A sensor starts to deflect.
So HVAC efficiency must become a recurring operation work.
The original HRT also proposed tracking data in different cycles and specifically emphasized that each indicator must have a responsible person and process when abnormal fluctuations occur.
I want the system to move from:
“How much electricity is used this month?"
sang:
“Where is the electricity changing, why and who will handle it?"
That's energy management.
A good program must help businesses invest smarter
Once you have good data, your business can decide on the next investment.
Do you really need to replace the Chiller?
Or just to modify the operation sequence?
Need to install variable-frequency drive?
Or is the existing system already in place but not yet logically driven?
Do I need to replace the entire VRF?
Or is it just a problem with some of the wrong zones?
CAPEX is no longer determined by feeling.
It is decided from the distance between:
Current status
and...
Status the system needs to reach.
That's how I want to use the data: not just to reduce electricity today, but to avoid a wrong investment tomorrow.
CEO's view Đoàn Văn Hoàng: I don't want to hear “saved”, I want to know how proven
When viewing a report HVAC efficiency assessmentI don't want to just see a percentage in blue.
I would like to know:
What range has the system been measured in?
How much load was that?
Is the quality of service maintained?
Has the cause of waste been identified?
What has been adjusted?
Is the before – after result eligible for comparison?
Who will keep the results after the consultant leaves the project?
That's how I apply the three values. True – Clear – Dedicated.
Understand Correctly data, load and cause of power consumption.
Clearly measurement range, objectives, limits and acceptance testing criteria.
Dedicated follow-up until results not only appear in one try but can be maintained in actual operation.
For me, the most important question is not:
“How much electricity can we reduce?"
It is:
“What electrical component is not creating value for the building, why does it exist and how to remove it without reducing service quality?”
When those three questions are answered, the savings program has a strong foundation.
Exchange HVAC efficiency assessment with HRT

For projects with increased HVAC electricity costs, it is recommended to start by gathering power data, operation schedule, setpoint, equipment status, load information and BMS data if available.
Then, it is necessary to define the boundary of assessment before selecting a solution.
Maybe the problem is with the operation.
Could be in maintenance.
It may also really need investment in renovation.
HRT aims to clarify the cause before proposing a solution, then measure again to confirm a demonstrable improvement.