HVAC resort hotel
Machine-translated from Vietnamese. Read the original in Vietnamese

HVAC resort hotels are not merely cooling the guest rooms. A good system must simultaneously address temperature, humidity, outdoor air, exhaust, noise, odor and operational costs. HRT analyzes HVAC solutions suitable for each area of the hotel and resort.
HVAC resort hotel – More than just cooling
In hotels and resorts, HVAC systems directly impact the guest experience.
A room that reaches the set temperature can still be badly judged if it has a blocky air, high humidity, smells, loud fan noises, or cold drafts that blow directly onto the bed.
So design HVAC hotel resort It should not start with the question “how much capacity to choose air conditioning?", but must start from the whole air experience in the building.
The system needs to coordinate simultaneously:
Air conditioner → outdoor air → exhaust → humidity control → differential pressure → Noise level → Control → Energy saving.
What does a good hotel HVAC system need to achieve?
The goal of HVAC is not just to keep the temperature in the comfort zone.
For hotels and resorts, the system needs to ensure stable temperature, good air quality, suitable humidity, low noise, no odor spread between areas and be able to operate under actual load.
This is especially important because hotels are constantly changing loads.
Guest rooms can be occupied at times, while empty; restaurants have rush hour; ballrooms can range from almost empty to hundreds of people; spas, gyms, kitchens, laundry areas and technical rooms have completely different characteristics.
A system designed to operate in a fixed mode is difficult to achieve long - term efficiency.
5 problems to decide the quality of HVAC resort hotels

1. Cooling load varies from time to time
Loads of hotels are not as stable as some manufacturing or office buildings.
Rooms with guests and empty rooms cannot operate the same. Lobby, restaurants, conference rooms and spas also have loads that vary according to the number of people and time of use.
Therefore, it is necessary to partition appropriately and select a system that can adjust the capacity according to actual load.
This is also the reason VRV/VRF solutions, chillers incorporating FCU / AHU or zone-based control systems are often evaluated right from the design stage.
2. outdoor air must be handled before put into space
Bringing in outdoor air does not mean that the outdoor air problem is solved.
In hot and humid climates, outdoor winds can carry significant amounts of heat and moisture.
If supplied directly to the room, the air conditioner must handle both thermal load and moisture load.
As a result, the room may still feel moist or condensation may occur in some locations.
Depending on the project, PAU, AHU, DOAS, ERV/HRV or suitable outdoor air handling configurations can be considered.
3. Suction discharge should be balanced with wind compensation
WC, kitchen, laundry room, garbage room and many auxiliary areas need to maintain exhaust suction.
However, exhaust suction is so large that lack of wind compensation can cause space to fall into an excessive negative pressure state.
The air outside or from other areas will then enter by itself through doors, technical slots and difficult to control locations.
The result may be odor spread, increased moisture load, difficulty opening and closing doors and imbalance of the entire system.
The correct design must consider simultaneously:
Supply air → outdoor air → wind compensation → exhaust air → differential pressure.
4. Humidity should be controlled together with temperature
24 degrees isn't necessarily comfort.
A space with low temperatures but high humidity can still feel cold, squashy, and uncomfortable.
For coastal resorts or humid climate areas, moisture loads are even more important.
If this factor is ignored, the building may appear a smell of moisture, mold, condensation, degradation of finishes or reduce interior life.
5. HVAC noise directly affects the resort experience
Hotel guest rooms have higher acoustical requirements than many other types of buildings.
The noise may stem from FCU, ventilation fan, AHU, PAU, air outlet, high wind speed, vibration of the equipment or inappropriate installation location.
Therefore, it is necessary to control right from the stage of equipment selection, determination of flow rate, pipe size, wind speed, sound absorption, vibration resistance and maintenance space layout.
Typical HVAC structures in hotels and resorts
A hotel HVAC project usually does not have just one type of equipment.
Depending on the size and grade of the project, the system can combine VRV / VRF for small partition areas; Chiller cold water supply for FCU or AHU; PAU outdoor air treatment; ERV / HRV energy recovery; exhaust system for WC, kitchen and auxiliary areas; BMS operation monitoring.
The key point is not how many devices are used, but whether the systems are working in sync.
A good FCU but lack of outdoor air is not enough.
A good PAU but not a good TAB flow rate is not likely to be effective.
A high-efficiency chiller with inadequate pump, valve and control operations can still consume large amounts of electricity.
Is a chiller or VRV/VRF more suitable for hotels?
There is no one answer for every project.
When can I consider VRV/VRF?
VRV/VRF often has the advantage of partitioning, independent control and flexibility according to the state of use of each area.
With hotels with multiple non-simultaneous operation rooms, this characteristic can offer significant advantages.
However, it is necessary to carefully check the length of the pipeline, the height difference, the location of the outdoor unit, the ability to ventilate, noise and maintenance.
When can Water Chiller be considered?
Chillers are typically rated for large hotels, resorts with significant cooling loads or buildings that need central refrigeration.
Chiller can combine FCU for break room, AHU for large space and PAU for outdoor air.
In return, the project needs to organize well the machine room, pump, chilled-water pipeline system, valves, control and maintenance.
Therefore, the choice should be based on the overall problem:
CAPEX + OPEX + technical space + lifetime + maintenance + operation method.
HVAC solution by each functional area
Rooms available
The rest room should prioritize low noise, the ability to adjust the temperature separately, the airflow does not blow directly into the bed, suitable outdoor air treatment and stable WC suction.
FCU or ceiling-concealed indoor unit also needs full sized visit door to clean coil, fan, filter and test condensate system.
Lobby and corridor
Lobby often bears a large penetration load because the main door is constantly open.
Corridors are more about pressure balance and odor control.
Bad designs can spread odors from your bathroom or living room to public transportation.
Restaurant and Kitchen
Restaurants need air conditioning and outdoor air.
Kitchen needs smoke extraction, heat suction, odor suction and compensation wind supply.
The two regions have a close relationship in terms of pressure but should not be considered as a similar system.
Ballroom and conference room
Ballrooms can have very high levels of fluctuating load.
Therefore, it is necessary to consider partitioning, controlling by event schedule, adjusting outdoor air according to demand and peak load capacity.
Spa and gym
Your spa needs to take moisture, odor, noise, and wind speed into account.
Gyms have high loads of people, the amount of CO2 and odor increases rapidly during peak hours, so ventilation must be properly organized.
Server and technical area
Server rooms may need constant cooling even when the hotel is offloaded at night.
Laundry rooms, warehouses, garbage areas and technical rooms often need to address ventilation, heat suction or odor suction.
It is not recommended to include them all in the same operation schedule.
7 common hotel resort HVAC errors

Select device before full load calculation
It's not enough to just calculate the area of the room and then select cooling capacity.
Must consider additional sunshine direction, glasses, people, equipment, outdoor air, moisture load, operation schedule and characteristics of each area.
Outdoor air is not heat treated – humid
This can cause cooling loads to increase but still make it difficult to maintain humidity.
WC suction but no wind compensation test
When the flow rate is imbalanced, air moves in unwanted directions, increasing the risk of spreading odors.
FCU without door maintenance
Small errors on drawings can cause huge costs during the operation phase.
When no inlet is available, cleaning the coil, treating condensate pumps, or repairing fans may require removal of the ceiling.
Design of wind speed too high
Smaller air duct does not mean more economical system.
High speed can increase the pressure drop, fan power and noise level.
Lack of coordination with interior and other MEP disciplines
Air outlet, lamps, speakers, sprinklers, alarms, curtains and decorative ceiling should be coordinated before construction.
Compare the initial investment price only
HVAC hotel operation many years.
The difference in electricity, maintenance and repairs over the lifetime of a building can be much greater than the original purchase price.
Where do I start to reduce hotel HVAC bills?
Energy savings do not mean mechanically reducing air conditioning capacity.
The right approach is to reduce the portion of energy that does not create value for the user.

Cooling load properties
Over-size device not only increases investment but also can make the system operate in the optimal load area.
Partition by utility
Guest rooms, restaurants, lobby, conferences, spas and back-of-houses have different operation schedules.
Reasonable zone separation helps reduce unnecessary device running time.
Control by room status
The system can be connected to key card, room controller, sensor or room management system.
When guests leave the room, the system can switch to save mode by itself instead of maintaining full capacity.
Adjust outdoor air according to demand
Ballrooms or restaurants aren't always full.
If the design is appropriate, adjusting the flow rate according to demand helps reduce the outdoor air handling load.
Energy recovery
ERV, HRV or appropriate recovery technologies can harness the energy from exhaust air flow to reduce the load on outdoor air.
Using variable-frequency drive
VFD can be considered for pumps, AHU, PAU and ventilation fans when the system has variable load.
Monitoring by BMS
BMS helps to monitor device status, schedule, temperature and operation alerts.
More importantly, operation data helps the engineering team detect equipment running overtime or abnormal parameters.
TAB and Commissioning
HVAC systems are only truly complete after they've been calibrated.
TAB and Commissioning help to test flow rate, temperature, pressure, control and coordination between devices.
Why TAB and Commissioning are so important to the hotel?
A correct drawing doesn't mean the actual system will run correctly.
In construction, pipe size deviation, pressure loss of fittings, improper damper adjustment, balancing valve incomplete or inappropriate control mode may appear.
TAB helps to adjust the flow rate.
Commissioning checks the entire operation logic.
The end result should be the system running in accordance with the design goals rather than simply “powered up device”.
HVAC deployment process for resort hotels in HRT
HRT approaches projects in series:
Surveying → Analysis → Designing → Separation → Construction → TAB/Commissioning → Handover → Maintenance & Optimization.
Survey and data collection
HRT evaluates the architecture, number of rooms, functions, direction of the work, technical area, climate conditions and expected operation method.
Analysis of cooling load and moisture load
Besides thermal load, outdoor air and moisture load should be considered from the beginning.
This is the foundation for equipment selection and building a strategy for temperature – humidity control.
System configuration options
Depending on the project, we can consider VRV/VRF, Water Chiller, FCU, AHU, PAU, ERV/HRV and ventilation systems.
Each solution must have specific technical and economic reasons.
MEP Design and Coordination
HVAC needs to coordinate with architecture, interior, electricity, water supply and drainage, fire protection and BMS.
Especially, it is necessary to check the maintenance space before finalizing the design.
Construction and Quality Control
Pipeline, air duct, thermal insulation, valve, condensate, electric control, anti-vibration and airtightness should be controlled throughout the construction process.
TAB, commissioning and commissioning
The system is calibrated and tested before handover.
Handover and maintenance
After being put into operation, the system needs periodic inspection and maintenance to maintain performance.
When should the hotel renovate the HVAC system?
A hotel doesn't have to replace its HVAC system when something goes wrong.
First, you need to identify the right cause.
Some signs that often need intensive survey include cold rooms but still humid, WC smell spreading to the corridor, FCU too noisy, condensation at air outlet, rooms with large temperature differences, increased electricity costs or frequent repairs.
The cause may lie in the equipment, but may also stem from air duct, outdoor air, exhaust, insulation, control or balance system.
Correcting the cause is more important than replacing a lot of equipment.
HVAC investment should look after the life cycle
HVAC is one of the major energy consumption systems of hotels.
So the best option is not necessarily the one with the lowest cost of equipment.
Project owner should look at total cost:
Initial investment + power + maintenance + repair + lifetime + operation downtime.
A properly designed system from the start can simultaneously improve customer experience and reduce long-term operation costs.
HRT – Comprehensive HVAC solution for hotels and resorts
HRT deploys the HVAC system in a synchronous direction from survey, consultancy, design, equipment supply to construction, TAB / Commissioning and maintenance.
For hotels and resorts, the goal of HRT is not just to create a space that is cold enough.
The ultimate goal is to:
More comfort – Cleaner air – Controlled humidity – quieter operation – More energy saving – More sustainable.
Source: Publisher’s English edition · Vietnamese original on doanvanhoang.com